D02 / DEVICE DEMANDS + C02 / CONTACT ACCESS

Give the motion
some room.

A numerical impact is not yet a mechanism. This iteration asks what must move, what must stay clear, and which force belongs to which part of the event.

Research direction: Ashley Kalkowski.
06 October 2026, 19:01 UTC · Numerical postprocessing and unbuilt CAD.

Original CAD rendering of the revised open-aperture crosshead concept
C02 / Original concept geometry. The open contact path is the subject of this revision.
144Existing input rows examined
18Existing full traces examined
0New dynamic integrations
0Physical tests

01 / THE MISSING CONNECTION

Launch. Contact. Rebound.

Before the simulation starts

The model assigns a speed to each released striker. A real device must first create that speed. D02 calculates ideal lower bounds on launch force, distance and time. No launcher is simulated.

During contact

The contact law determines a collision force as the striker and specimen move. That force is not the earlier launcher command. D02 reconstructs impulse and work from the saved motion and checks the accounting.

After separation

A striker can continue moving after the recording ends. The measured-in-model 0.17-second travel span does not specify a complete guide, catcher or reset mechanism. No stopping design is validated.

The parent is an uncalibrated elastic cantilever with ideal released strikers. Attached shaker armatures, preloaded piezo elements and guided powered stages have different dynamics. This study does not silently substitute one for another.

02 / THE RETAINED NUMERICAL EVIDENCE

Account for the motion.

All36 source histories end with nonzero striker velocity. The largest observed0.17-second span is72.069630mm; the largest sampled contact force is25.093330N. These extrema come from different retained histories; each identity is recorded in the JSON.

Finite-window motion envelopes
Finite-window motion envelopes Saved motion with continuing endpoint travel, not a complete catcher stroke.
Ideal launch demands
Ideal launch demands Necessary net mechanical force and distance bounds for the frozen assignments.
ProfileForce capStrokeFailed boundsMet bounds
H010.1 N5 mm288 / 288 fail0 / 288 pass necessary screen
H020.5 N10 mm0 / 288 fail288 / 288 pass necessary screen
H032 N5 mm0 / 288 fail288 / 288 pass necessary screen
H045 N2 mm0 / 288 fail288 / 288 pass necessary screen

The four force/stroke profiles were fixed before postprocessing. They are hypothetical net mechanical caps, not product specifications. A passed energy inequality is a necessary ideal screen only; it does not establish a working actuator, a budget, or a fracture result.

Exact counts, numerical checks and preserved failures

144 existing input rows,288 striker assignments,1,152 algebraic screens,18 full traces and36 motion histories. No new integration. All13 author tests and the separate full computational audit passed. All R07 input hashes were retained. Failed necessary launch screens remain in the result records.

Full derived result JSON · Separate computational review · Frozen plan

03 / A SPECIFIC CAD CORRECTION

Open the contact path.

The C01 Duet concept puts its heads over solid carriage plates. For a head approaching a specimen underneath, that plate is an obstruction. C02 makes the path explicit and tests clearance against the generated geometry.

The revised polygonal apertures retain a minimum1.488756mm geometric margin after the explicitly assumed0.5mm radial positioning allowance. Undersized and touching controls remain documented.

Assembly
Assembly Original generated rigid geometry.
Exploded view
Exploded view Concept parts and open crosshead.
Section and motion
Section and motion Finite-time trajectory overlay does not define complete travel.
Dimensions
Dimensions Nominal dimensions and assumed positioning allowance.
CheckNominal model result
Minimum guarded port-edge margin1.488756 mm
Rail margin28.5 mm
Post margin24.5 mm
Head-to-head guarded margin21 mm
Undersized port controlInterference, as expected
Exact nominal tangency controlTouching, as expected

The revision uses a stated lateral separation between two ports. The one-dimensional R07 reference can place both ideal forces at the same axial point; it does not resolve this lateral layout or its torsional effects. The geometry is not a verified implementation of that simulation.

Geometry checks cover the declared aperture and motion envelope. Component fit, fasteners, stiffness, cable routing, actual travel drive, capture, thermal behavior and physical performance remain engineering tasks. The original C01 files stay unchanged and accessible.

Compare the original concept family · C02 geometry checks

04 / CHANGE THE ASSUMPTIONS

What does the launch require?

Explore a separate, ideal launch from rest. The force cap is the net accelerating force on the chosen moving mass. Gravity, friction, driver dynamics, attached mass, transfer losses and reset are excluded.

Kinetic energy is ½mv². With a nonnegative net force bounded by F, the minimum ideal stroke is E/F and the minimum ideal time is mv/F. A constant force over the chosen stroke would require E/s. This calculator does not find a resonant frequency, drive hardware or select a device.

05 / READ THE RATINGS IN CONTEXT

One impressive number is not an operating point.

Electrodynamic shaker

Sine peak, random RMS, shock peak and travel are separate ratings. They do not describe a single simultaneously achievable operating point.

Primary specification

Guided voice-coil stage

An attached armature or moving stage changes the mass and dynamics. Continuous force, duty-limited force, stroke and back EMF constrain different parts of the event.

Primary specification

Piezoelectric actuator

Free displacement and blocked force are endpoints of a load-dependent relationship. Preload, stiffness and frequency affect the operating displacement.

Primary specification

These primary sources explain specification boundaries. No product is selected, priced or certified as compatible. Third-party PDFs and product imagery are linked rather than redistributed.

Source register and access notes

06 / REPRODUCE THE CHECK

Keep the evidence inspectable.

D02 code and derived evidence

Trace postprocessing, ideal launch bounds, tests, frozen plan, results, independent verification and generated plots. Original R07 traces remain separate downloads.

Download D02 · 0.63 MB

SHA-256
9ec63cc50e53ed5286bcf07a31ad9043d519f7b2291cb2520695040ae4b1d72d

C02 editable geometry

Parametric source, part meshes, assembly views, geometric clearance checks and deliberately failing controls. An unbuilt geometry study.

Download C02 · 0.99 MB

SHA-256
17a1cede9b0e75a60eb737a595514d58c1702018fc14aba63797375ec6718b12

Exact public file manifest · Parent R07 source and full traces

D02 portable supplement - public packaging instructions

Place device-demand/ beside efficiency/ from the prior numerical releases.
The calculator uses Python 3.10+ and NumPy 1.26+. Plotting also uses Matplotlib.
The 13 author unit tests and ideal launch CLI do not require the R07 archive.

From device-demand/:

  python -m unittest test_device_demand -v
  python device_demand.py launch --mass-kg 0.01 --speed 1 --force-cap 0.5 --stroke 0.01 --output launch-001

To reproduce all D02 numerical outputs, first extract the R04, R05, R06 and
R07 core overlays and obtain all 18 separate R07 NPZ files. Preserve their
recorded paths under efficiency/results/iteration07/traces/. Then:

  python device_demand.py study --r07-root ../efficiency --output rerun-001

To regenerate the published figures using the provided frozen summary:

  python plot_demands.py --summary results/D02_summary.json --output figures-rerun-001

Every output argument above must name a new path. Existing evidence is
refused, including an existing empty directory. A numerical rerun can have
different elapsed time and its source inventory can include the optional
plot script added after the original calculation freeze. This does not
alter the original report's four-file source map. Compare numerical fields
and retained input hashes, not the entire JSON file's hash across reruns.

The final published figure directory is figures-v2/. Its separate manifest
binds the plotting source, exact D02 summary and all seven plot/data files.
The first figure layout was retained privately; v2 fixes legend placement.
No numerical input, trajectory, or calculation result changed for the plots.

PUBLIC-FILES.json is an exact allowlist relative to device-demand/. It does
not include itself, local bytecode, prior drafts, parent archives or traces.
The independently prepared reviewer public subset is packaged separately
from output/device-demand-review/public using its own exact allowlist.

D02 performs 1,152 algebraic source/profile screens and derives 36 histories
from 18 existing full traces. It runs zero new trajectory integrations and
zero physical trials. Its four force/stroke profiles are hypothetical. The
observed 0.17 s motion window is not complete launch, guide or catcher travel.
All 36 strikers are still moving at the endpoint. No hardware capability,
fracture, heat limit, repeat-cycle throughput or assembly fit is validated.

Extract to a fresh folder and follow the included README. Preserve the original evidence when reproducing calculations. Python and its listed dependencies are separate installations. The programs do not operate instruments.

07 / WHAT MUST IMPROVE NEXT

Turn clear space into a tested interface.

Continue to the E01 component assemblies and operating models

The next physical connection needs a specified moving assembly, measured force and motion, a known contact geometry and a complete energy boundary. A clear port does not prove that a housing can carry a load; a favorable energy bound does not identify a viable actuator. Calibration and withheld-condition tests must precede claims about a chosen split in rock.

Research direction: Ashley Kalkowski. Computational implementation and review used Codex assistance. Established mechanics and dependency terms remain attributed. This release makes project files inspectable; it does not add a blanket reuse licence or a patent-status claim.