  "schema_version": 1,
  "study_id": "D02-MANUFACTURER-CONTEXT",
  "created_utc": "2026-10-06T18:37:33.563738+00:00",
  "status": "PRIMARY_DOCUMENT_CONTEXT_NOT_HARDWARE_SELECTION",
  "sources": [
    {
      "id": "MFR01",
      "manufacturer": "The Modal Shop / PCB Piezotronics",
      "title": "SmartShaker K2004E01 / K2007E01, DS-0079 revF",
      "url": "https://www.modalshop.com/docs/themodalshoplibraries/datasheets/k200xe01-smartshaker-with-integrated-power-amplifier-datasheet-ds-0079.pdf?sfvrsn=ebd53789_12",
      "access": "Official PDF downloaded with TLS verification; both pages read and rendered for visual inspection.",
      "source_sha256": "76108c5fa217b4f704e53d01be81e0e5cdc76462ec86fe704094291d50c770f3",
      "pages_used": [
        1,
        2
      ],
      "facts": {
        "example_model": "K2007E01",
        "sine_peak_force_n": 31,
        "random_rms_force_n": 22,
        "shock_peak_force_n": 67,
        "continuous_peak_to_peak_stroke_m": 0.013,
        "between_stops_stroke_m": 0.014,
        "frequency_range_hz": [
          0,
          9000
        ],
        "frequency_limit_load_dependent": true,
        "armature_mass_kg": 0.045,
        "attachment": "Threaded table and supplied flexible nylon stingers; a supported reaction base is part of the instrument."
      },
      "interpretation": "Distinct sine, random and shock ratings cannot be interchanged. Full stroke and highest frequency are not a simultaneous operating point. Attached armature and suspension dynamics differ from a released 10 g striker.",
      "missing": "No maximum velocity curve, achieved launch profile, price or whole-system mechanical efficiency established here."
    },
    {
      "id": "MFR02",
      "manufacturer": "H2W Technologies",
      "title": "Voice Coil Linear Positioning Stage VCS24-029-LB-03",
      "url": "https://www.h2wtech.com/product/voice-coil-stages/VCS24-029-LB-03",
      "access": "Official product page and specification table read live.",
      "facts": {
        "force_at_100_percent_duty_n": 12.9,
        "force_at_10_percent_duty_n": 38.7,
        "stroke_m": 0.061,
        "moving_mass_kg": 0.726,
        "total_stage_mass_kg": 0.894,
        "electrical_time_constant_s": 0.0012,
        "back_emf_v_per_m_s": 5.5,
        "attachment": "Guided linear-rail stage, not a free projectile."
      },
      "interpretation": "Peak intermittent force is not continuous force. Driver dynamics, velocity and moving mass must be included before mapping a trajectory onto this stage.",
      "source_ambiguity": "Prose identifies a moving coil; the table identifies a moving magnet assembly. This review does not resolve the conflict or use moving-member identity.",
      "missing": "No verified maximum velocity, pulse-duration envelope, delivered efficiency or price."
    },
    {
      "id": "MFR03",
      "manufacturer": "Physik Instrumente / PI Ceramic",
      "title": "Piezoelectric Actuators catalog CAT128E_R3, Forces and Stiffnesses / Dynamic Operation",
      "url": "https://www.physikinstrumente.com/fileadmin/user_upload/pi_ceramic/files/catalog_CAT/PI_CAT128E_R3_Piezoelectric_Actuators.pdf",
      "access": "Official PDF downloaded with TLS verification; printed pages 52-56 read and rendered for visual inspection.",
      "source_sha256": "784aaf66b81464b76f8d1968b543f3db8ad9705e009d30d8ad06d4c0c29b2dfc",
      "pages_used": [
        52,
        53,
        54,
        55,
        56
      ],
      "facts": {
        "free_displacement_definition": "Travel measured without opposing load.",
        "blocking_force_definition": "Force with displacement constrained to zero.",
        "dynamic_example": {
          "frequency_hz": 1000,
          "peak_to_peak_displacement_m": 2e-06,
          "effective_mass_kg": 1,
          "approximate_dynamic_force_amplitude_n": 40
        },
        "preload_and_attachment": "Load stiffness and lateral guidance matter; preload counteracts tensile loading, with model-specific limits."
      },
      "interpretation": "Blocking force and free travel are endpoints of a working curve, not a constant-force rectangle. Added mass changes resonance. Mechanical-load transfer and amplifier losses belong in a complete energy boundary.",
      "missing": "No specific piezo model, arbitrary-material coupling or fracture performance selected or validated."
    }
  ],
  "scope": "Manufacturer examples explain rating definitions. They are separate from the four D02 hypothetical force/stroke profiles.",
  "source_documents_redistributed": false,
  "source_cache_scope": "Third-party PDFs/renderings are retained privately for verification and excluded from public allowlists.",
  "price_or_under_1000_usd_claim": false,
  "device_recommendation": false,
  "physical_validation": false,
  "general_analytic_bounds": [
    "A separate ideal launch of a 10 g striker to 1 m/s requires 5 mJ and 0.01 N s of impulse.",
    "With net nonnegative force bounded by Fcap, E <= Fcap*s and m*v <= Fcap*t are necessary.",
    "The work bound is an integral of force over motion. Product peak force multiplied by independent catalog stroke is not an achieved work measurement.",
    "A pre-t0 launcher force is distinct from the subsequent collision force; energy stored before contact can produce a shorter, higher contact-force pulse.",
    "For sinusoidal displacement with peak-to-peak stroke S, peak velocity is pi*f*S and peak acceleration is 2*pi^2*f^2*S. These are kinematic identities, not a declaration that catalog maxima coexist.",
    "A coupled armature, fixture, preload spring or reaction mass changes the physical model. Passing an ideal launch screen does not validate a product or a fracture test."
  ]
}