  "schema": "e02-reset-primary-source-register-v1",
  "created_utc": "2026-10-06T20:22:50.843419+00:00",
  "scope": "Focused source research for the existing captive low-energy E01 impact reference; no new dynamics or physical tests.",
  "baseline_file": "E01-GEOMETRY-BASELINE.json",
  "sources": [
    {
      "id": "S1",
      "publisher": "Pololu",
      "title": "20.4:1 Metal Gearmotor 25Dx65L mm LP 12V with 48 CPR Encoder, item4883",
      "url": "https://www.pololu.com/product/4883",
      "document_date": null,
      "date_note": "No publication date stated on reviewed product page.",
      "locator": "Specifications; encoder; dimensions; stall warning",
      "catalog_facts": {
        "nominal_voltage_v": 12,
        "no_load_output_speed_rpm": 280,
        "no_load_current_a": 0.06,
        "extrapolated_stall_torque_kgf_cm": 2.4,
        "extrapolated_stall_current_a": 0.9,
        "case_diameter_mm": 25,
        "output_shaft_diameter_mm": 4,
        "encoder_counts_per_motor_revolution": 48
      },
      "summary": "The gearmotor provides rotation and encoder feedback; it is not a complete lifting or release mechanism. Pololu labels stall figures as extrapolations, warns of heating damage and gives a general brushed-motor current recommendation of no more than one quarter of stall current. No-load speed and stall torque do not occur together. The encoder counts motor rotation; gearing and backlash separate this from carriage position.",
      "does_not_establish": [
        "Cam profile or tab fit",
        "Continuous loaded operating point for E01",
        "Release clearance or latch confirmation",
        "No-solder complete electrical chain"
      ],
      "accessed_date": "2026-10-06",
      "evidence_type": "primary_manufacturer_document",
      "hardware_selected": false
    },
    {
      "id": "S2",
      "publisher": "Oriental Motor",
      "title": "Selection Calculations, General Catalog2012/2013",
      "url": "https://www.orientalmotor.com/products/pdfs/2012-2013/G/usa_tech_calculation.pdf",
      "document_date": "2012/2013",
      "date_note": "Historical manufacturer technical reference, not current product availability.",
      "locator": "PrintedG-2 toG-5, PDFpages2\u20135",
      "catalog_facts": {},
      "summary": "Motor selection starts from mechanism geometry, mass, friction, positioning time, speed and holding needs. Load and acceleration torque must be checked at operating speed; repeated acceleration also requires an effective torque assessment. This supports measuring the reset load throughout the motion, rather than choosing a motor by stall torque.",
      "does_not_establish": [
        "Any selected E01 cam or motor",
        "New mechanism novelty",
        "Prototype life or measured efficiency"
      ],
      "accessed_date": "2026-10-06",
      "evidence_type": "primary_manufacturer_document",
      "hardware_selected": false
    },
    {
      "id": "S3",
      "publisher": "Johnson Electric / Ledex",
      "title": "Ledex Open Frame DC Solenoids",
      "url": "https://www.johnsonelectric.com/pub/media/image/tmp/metric-imperial/20200212_Open_Frame_DC_in.pdf",
      "document_date": null,
      "date_note": "Filename includes20200212; this is not treated as a verified publication/revision date.",
      "locator": "PDFpages2\u20135; design considerations and latching selection table",
      "catalog_facts": {
        "catalog_family_stroke_up_to_mm": 25.4,
        "listed_B14_L_max_stroke_mm": 12.7,
        "listed_B14_L_nominal_stroke_mm": 3.81,
        "listed_B14_L_typical_force_at_nominal_stroke_25pct_duty_lbf": 1.5,
        "force_curve_ambient_c": 20
      },
      "summary": "The catalog separates force-versus-stroke curves by duty cycle and notes that coil heating reduces output. Magnetic-latching versions can retain their plunger state without steady holding power; that feature does not establish retention or release of a separate loaded pin. A selected B14-L family row has12.7mm maximum travel, below the E01 pin\u2019s34mm clearance requirement.",
      "does_not_establish": [
        "Direct replacement of the E01 pin",
        "Loaded extraction force or response time",
        "Gravity-carriage lift capability",
        "Fail-safe state of a complete mechanism"
      ],
      "accessed_date": "2026-10-06",
      "evidence_type": "primary_manufacturer_document",
      "hardware_selected": false
    },
    {
      "id": "S4",
      "publisher": "Actuonix Motion Devices",
      "title": "L12-100-100-12-S product",
      "url": "https://www.actuonix.com/l12-100-100-12-s",
      "document_date": null,
      "date_note": "Product page has no revision date; price and stock excluded.",
      "locator": "Product Features",
      "catalog_facts": {
        "stroke_mm": 100,
        "gear_ratio": 100,
        "nominal_voltage_v": 12,
        "max_load_n": 42,
        "no_load_speed_mm_s": 13,
        "static_backdrive_force_n": 22,
        "closed_hole_to_hole_mm": 152,
        "total_mass_g": 56
      },
      "summary": "The100mm stroke exceeds the nominal E01 reset excursion on paper. Its152mm closed mounting length and22N static backdrive figure mean that direct attachment cannot be assumed to fit the frame or permit a12g carriage to fall freely. It is a reset-drive reference requiring a separate disengaging connection.",
      "does_not_establish": [
        "Mounting compatibility",
        "Free-fall disengagement",
        "Loaded reset speed",
        "Continuous rapid repetition"
      ],
      "accessed_date": "2026-10-06",
      "evidence_type": "primary_manufacturer_document",
      "hardware_selected": false
    },
    {
      "id": "S5",
      "publisher": "Actuonix Motion Devices",
      "title": "L12 Datasheet, RevisionF",
      "url": "https://www.actuonix.com/assets/images/datasheets/ActuonixL12Datasheet.pdf",
      "document_date": "2019-11",
      "date_note": "RevisionF, November2019 printed on PDFpage4; linked by the current product page.",
      "locator": "PDFpages1\u20132 and revision onpage4",
      "catalog_facts": {
        "maximum_duty_fraction": 0.2,
        "100_ratio_peak_efficiency_load_n": 17,
        "100_ratio_speed_at_peak_efficiency_mm_s": 10,
        "100_ratio_peak_power_load_n": 31,
        "100_ratio_speed_at_peak_power_mm_s": 7,
        "mechanical_backlash_mm": 0.2
      },
      "summary": "The datasheet pairs load with speed and caps duty at20%. End-switch S control stops only near the fixed ends of travel; it is not arbitrary-position feedback. The12V stall-current entry is246mA in this revision, illustrating why older distributor values cannot substitute for the linked manufacturer document. Application life still requires testing.",
      "does_not_establish": [
        "A universal duty averaging window",
        "E01 closed-loop position calibration",
        "Impact-load rating",
        "Any electrical energy recovery"
      ],
      "accessed_date": "2026-10-06",
      "evidence_type": "primary_manufacturer_document",
      "hardware_selected": false
    },
    {
      "id": "S6",
      "publisher": "H2W Technologies",
      "title": "VCS24-029-LB-03 Voice Coil Linear Positioning Stage",
      "url": "https://www.h2wtech.com/product/voice-coil-stages/VCS24-029-LB-03",
      "document_date": null,
      "date_note": "No revision/publication date shown on reviewed page.",
      "locator": "Product description and parameter table",
      "catalog_facts": {
        "stroke_mm": 61,
        "continuous_force_n": 12.9,
        "force_at_10pct_duty_n": 38.7,
        "moving_mass_g": 726,
        "continuous_current_a": 2.4,
        "current_at_10pct_duty_a": 7.2,
        "continuous_power_w": 25,
        "power_at_10pct_duty_w": 225,
        "encoder_resolution_um": 3,
        "force_constant_n_a": 5.5,
        "back_emf_v_per_m_s": 5.5,
        "resistance_at_20c_ohm": 4.5,
        "inductance_mh": 5.4
      },
      "summary": "This reference distinguishes continuous and10%-duty peak force and lists61mm stroke and726g moving mass. It fails a direct85mm reset stroke screen and would greatly change the12g impact model if attached throughout the drop. The description says moving coil while its table says moving magnet; that inconsistency is unresolved, so it is not selected hardware.",
      "does_not_establish": [
        "Maximum loaded velocity for E01",
        "A compatible stroke or moving mass",
        "Which assembly actually moves",
        "An amplifier, release system or repetition rate"
      ],
      "accessed_date": "2026-10-06",
      "evidence_type": "primary_manufacturer_document",
      "hardware_selected": false
    }
  ],
  "architectures": [
    {
      "id": "A1",
      "name": "Stationary geared motor with cam or lifting fork and separate latch",
      "source_ids": [
        "S1",
        "S2"
      ],
      "status": "Unbuilt architecture hypothesis; first candidate for geometry and load characterization, not a selected product.",
      "mechanism": "Lift the rear reset tab, retain the raised carriage on a positive latch, then retract the lifting contact before releasing. A cam alone must not be assumed to produce free fall; follower contact, side loads and the return path must be modeled.",
      "essential_limits": [
        "Required lift includes the measured capture position below the target datum.",
        "Motor shaft torque must cover gravity, measured guide friction, reflected inertia and cam geometry at actual speed.",
        "The existing34mm pin clearance and5mm upper geometric margin remain separate constraints.",
        "A motor encoder does not prove that the carriage is latched or the lift is disengaged."
      ],
      "falsification_tests": [
        "Measure quasi-static upward and downward carriage force versus position, including breakaway.",
        "Measure cam/fork force, shaft angle, carriage position, positive and absorbed work through a complete lift/return.",
        "Verify zero lifting-contact force throughout the full drop corridor and capture motion.",
        "Record release-height variation, pin-clearance time, missed latches and thermal drift over a predeclared cycle count."
      ],
      "materials_to_characterize": [
        "Metal pivot/shaft and mechanically retained pins with specified finish and dimensions.",
        "Candidate acetal or metal cam/follower contact; wear and creep remain unqualified.",
        "Frame, bushings and lift tab must be checked for side-load deformation and fatigue."
      ]
    },
    {
      "id": "A2",
      "name": "Independent lift plus a solenoid-operated release latch",
      "source_ids": [
        "S3"
      ],
      "status": "Latch actuation hypothesis only; does not supply an85mm reset lift.",
      "mechanism": "Use a separate lifting subsystem; a small solenoid may actuate a redesigned short-travel sear or lever. It cannot directly replace the present34mm-withdrawal pin without a different transmission or longer travel. A lever trades travel for force and adds friction.",
      "essential_limits": [
        "Pull-in force at the initial gap and hot coil matters, not only holding force near the seated position.",
        "Measure loaded extraction force and magnetic residual holding; carriage weight alone does not determine these.",
        "Positive retention, commanded release and loss-of-power behavior are different requirements.",
        "Any latch spring stores energy and may perturb the drop; account for its work."
      ],
      "falsification_tests": [
        "Measure force versus full latch stroke cold and at the maximum intended temperature.",
        "Load the latch with the actual carriage and measure extraction force, release delay and variation.",
        "Demonstrate latch-clear confirmation and verify that the sear does not graze the falling carriage.",
        "Measure pulse energy, holding energy if applicable, coil temperature and repeatability over the declared duty pattern."
      ],
      "materials_to_characterize": [
        "Metal load-bearing sear/pin with rounded controlled contact geometry; hardness and wear need specification.",
        "Bushings and brackets with measured alignment and compliance.",
        "Return spring material, preload and fatigue rating only after its required motion is known."
      ]
    },
    {
      "id": "A3",
      "name": "Linear reset drive with an independently disengaging pickup",
      "source_ids": [
        "S4",
        "S5",
        "S6"
      ],
      "status": "Long-stroke geared-drive reference plus a rejected direct-fit voice-coil example; neither selected.",
      "mechanism": "A guided linear drive raises the existing carriage through a pickup that releases mechanically after a separate latch is seated. The drive retracts outside the entire drop corridor. Retaining a powered actuator during impact would be a new driven-impact model, not the E01 free-drop reference.",
      "essential_limits": [
        "The L12 reference has enough catalog stroke but unknown installation fit and a low duty limit.",
        "At13mm/s no-load speed,85mm alone takes at least6.54s under the nominal catalog envelope; actual loaded reset, return and latch time add delay.",
        "The61mm H2W example cannot meet the required lift directly; a travel-amplifying linkage changes force, inertia and packaging.",
        "Voice-coil peak force cannot be sustained continuously; required supply voltage also grows with speed through back EMF."
      ],
      "falsification_tests": [
        "Measure available force and velocity together across the full intended travel and supply conditions.",
        "Verify pickup release and parked clearance with worst-case tolerance and capture positions.",
        "Measure true carriage mass independently of actuator moving mass.",
        "Measure electrical input and both signs of mechanical work; do not count absorbed work as returned electrical energy without evidence."
      ],
      "materials_to_characterize": [
        "A guided metal pickup and pinned attachment with no residual tether tension.",
        "Bushings/rollers and fasteners sized from measured alignment and side loads.",
        "Retain the current capture pads as unqualified until stiffness, dissipation and permanent set are measured."
      ]
    }
  ],
  "shared_measurement_requirements": [
    "Weigh the complete actual falling assembly.",
    "Measure guide stiction and sliding friction in both directions.",
    "Record lift, latch, disengagement, fall, rebound, capture and settling as distinct phases.",
    "Define repeat cadence from the entire measured cycle, including thermal off-time; no-load actuator frequency is not strike frequency.",
    "Keep commanded actuator work, dissipated/absorbed work and measured electrical input separate."
  ],
  "claims_boundaries": [
    "No manufacturer part is selected, fitted, purchased or tested.",
    "No price, stock, complete budget, optimum efficiency or achievable cycle rate is claimed.",
    "Catalog data are source examples, not measured specimen/actuator inputs.",
    "The three architectures use established mechanism families; no patentability or novelty finding is made.",
    "Only original summaries and links are included; vendor PDFs, figures, CAD and wiring diagrams are not redistributed."
  ]
}