E01 ELECTRICAL INTERFACES AND BENCH CHARACTERIZATION
Authored engineering review, 6 October 2026

The present operating model takes actual RMS voltage across the driver as its
input. A computer volume setting is not that voltage. The complete electrical
chain still needs physical calibration before any model-to-hardware claim.
No hardware was powered or measured for this document.

PROPOSED WIRED CHAIN
Computer audio application -> selected analog output or USB audio DAC ->
3.5 mm audio cable -> Dayton KAB-FC AUX harness -> KAB-215v2 amplifier ->
separate speaker output pair -> ND64-4 or ND91-4 in the declared enclosure.
An enclosed external low-voltage DC supply powers the amplifier separately.
The amplifier is not itself a USB measurement interface. USB audio hardware,
recording inputs, sensors, supply model and exact end connectors remain parts
to select and characterize. Bluetooth is outside the deterministic timing path.

VERIFIED MANUFACTURER INTERFACES
The amplifier's official guide identifies its included power/speaker harnesses,
the optional AUX harness, and the AUX jumper that must be removed. Use the
matched harness and the illustrated orientation. The driver end of that harness
is not thereby proven to fit a speaker tab without soldering. Driver terminal
width, thickness, mating connector and pull-out clearance remain unresolved.
The source supports a 12-24V DC supply range and 4-8ohm nominal speaker load;
its 2x15W rating is specified at19V into8ohms, not at every operating condition.
https://www.daytonaudio.com/images/resources/325-500--dayton-audio-kab-215v2-quick-start-wiring-guide.pdf
https://www.daytonaudio.com/product/1871/kab-215v2-2-x-15w-class-d-audio-amplifier-board-with-bluetooth-5-0
https://www.daytonaudio.com/product/1394/kab-fc-functional-cables-package-for-bluetooth-amplifier-boards

OUTPUT GROUNDING AND MEASUREMENT
Each speaker belongs between its own marked plus/minus output pair. The
negative output is not assumed to be computer, supply or oscilloscope ground.
Do not tie channel outputs together or attach an earth-grounded probe clip to
an output terminal. A differential measurement interface must have suitable
input range, common-mode range, isolation/grounding arrangement and bandwidth.
Class-D switching components can corrupt an unqualified RMS meter or sound
card input; use an appropriate measurement front end and documented filtering.
Do not connect amplified speaker outputs directly to a PC microphone/line input.
TI's manufacturer notes establish these general differential/Class-D measurement
principles; they are not a schematic certification of the Dayton board.
https://www.ti.com/lit/an/sloa116/sloa116.pdf
https://www.ti.com/lit/an/sloa068a/sloa068a.pdf

CHARACTERIZATION SEQUENCE — PROPOSED, NOT PERFORMED
1. Record the physical component revisions, measured mounting interfaces,
   actual enclosure air-volume basis, complete signal path and supply. Resolve
   polarity/connector/insulation/strain-relief issues before applying power.
2. Establish the measurement chain's gain, phase, bandwidth and uncertainty
   with its documented calibration procedure. Record instrument and probe
   models, calibration dates, ranges, filters and grounding diagram.
3. With the intended load and conservative initial drive, measure differential
   terminal voltage at the model's test frequencies. Record digital amplitude,
   computer/DAC settings and amplifier volume position; these settings are only
   reproducibility metadata, not substitutes for measured volts.
4. Confirm unclipped waveform behavior, channel polarity, frequency response,
   left/right phase and repeatability. Change the amplifier/supply/cable only as
   a new configuration. Measure the output again after changes. Do not infer a
   fixed gain or latency from an undocumented amplifier setting.
5. For driver comparison, acquire voltage and current with synchronized,
   calibrated channels and compare complex impedance against the declared
   model. If using a series current-sense element, include its calibrated value,
   phase behavior and added series impedance in the model and uncertainty.
6. Measure cone motion separately when validating displacement. An enclosure
   pressure estimate is not measured external SPL, and an accelerometer added
   to a small cone changes its moving mass. Record that loading if used.
7. Compare repeated measurements with the model plus the measured uncertainty.
   Preserve discrepancies, temperature drift and rejected runs. Do not adjust
   the model after looking at a result and still label that result a prediction.

WHAT THE MODEL DOES AND DOES NOT ACCOUNT FOR
The reciprocal three-state model includes coil resistance/inductance, back EMF,
motor force, effective moving mass, suspension, aggregate mechanical damping
and ideal sealed-air stiffness. Its power balance is internal to that model.
The aggregate mechanical-loss term is not independently measured acoustic
power. The calculation does not separate radiation from suspension losses,
predict a beam of sound, or predict specimen fracture. The Dayton Mms already
includes air load; another full radiation mass must not be added silently.

For a reactive speaker, real output power is the time average of v(t)i(t), or
the real part of the RMS complex power for a steady sinusoid. Vrms^2 divided
by nominal4ohms is not a valid general loudspeaker power measurement. Amplifier
DC input power and wall input power are separate measurements with different
boundaries. Record idle energy, startup, electronics, sensors and any repetition
or reset hardware if later making whole-system efficiency claims.

BUILD STATUS
The PC-to-amplifier architecture is specified at interface level. A completely
solder-free chain, exact PCB carrier holes, supplied driver fit and measured
operation have not been established. There is no physical fracture result in
this package. The next useful evidence is a calibrated low-amplitude electrical
and motion measurement of the assembled head, not a higher unmeasured setting.